SIZE 4.5" wide x 10.5" high x 9.1" deep.
POWER REQUIREMENTS 89 to 135 volts ac.
60 +/- 3 Hertz 1 Amp SLO-BLO fusing
TEMPERATURE -34°C to +74°C Operating       -40°C to +85°C Storage
CHANNELS MONITORED 12 Channels with 4 inputs / channel (Green, Yellow, Walk, Red / Don't Walk).
MONITORED SIGNALS Controller Voltage Monitor.
+24 Volt dc. (24VI and 24 VII)
48 ac field wire voltages (both polarities of sinusoid are monitored independent of one another).
DISPLAYED INFORMATION All active channels on 4 line x 20 character LCD.

THE FOLLOWING SHOWS OUTPUT TRANSMISSIONS OBTAINED ACROSS THE RS232 PORT BY ACCESSING THE FRONT PANEL KEYPAD. THE OUTPUT SHOWN HERE WAS ALSO DISPLAYED CONCURRENTLY ON THE LCD AS EACH TRANSMISSION WAS PRINTED TO AN 80 COLUMN WIDE SERIAL PRINTER.
Copyright (c) 1993
Traffic Sensor Corp.
Rev. G 2/9/93
>HELP
TIME hour:min:sec
DATE month/day/year
FAULT Disp Faults
PFAULT Print Faults
MESSAGE Disp Mess
PMESSAGE Print Mess
CLEAR Clear Data
PLOG Print Log
CLEARLOG Clear Log
PGCARD Disp. Prog. C.
COM Set up RS 232
ID Location Ident.
FLASHDLY Rly Dly
ANALOG Disp Line V
SETUP Setup Opt.
ERASE Setup Erase
DSPSETUP Disp. Setup
SELFTEST Self Test
DONE

>TIME
TIME 10:12:52
>DATE
DATE 04/25/93
>PFAULT
SITE FFFF FFFF DATE 04/25/93 TIME 10:13:03
# DATE TIME 111 TEMP AC 24Vl FAULT 123456789012 (F) LINE MON 000 4/22/93 15:53 RYRGRYGG 55 105 24 CONFLICT 6Y 7G
010 4/20/93 15:46 GGYRGRRR 55 104 23 CONFLICT 1G 2G
020 4/17/93 15:57 RGRGRGGR 55 106 24 MULT IND 7Y 7G
030 4/17/93 13:27 GGYRGRRR 65 105 24 MIN FAIL 8R
>PMESSAGE> SITE 1127 3423 DATE 04/25/93 TIME 10:13:14 # DATE TIME 111 TEMP AC 24V1 MESSAGE 123456789012 (F) LINE MON
00 04/22/93 16:04 G Y R W 77 99 24 NO PROG CARD 01 04/20/93 10:22 W R GY 55 92 22 POWER FAIL
02 04/18/93 15:55 GYWRRRRR 64 105 22 MIN FAIL 7Y
03 03/23/93 08:27 RGWRGYRG 57 108 23 MIN FAIL 4Y

>CLEAR
ARE YOU SURE yes=l 1
FLT--O MSG=L BOTH=2 2
CLEARED MSG & FAULT
RESET

>PLOG
SITE 1127 3432 DATE 04/25/93 TIME 10:13:30
04/25/93 10:11 FRONT PANEL RESET
04/25/93 10:11 SET UP
04/22/93 16:04 POWER UP
03/06/93 14:10 CLEAR LOG

>CLEARLOG
ARE YOU SURE yes=l I
DONE

>PGCARD >COM
BAUD RATE 9600
PROGRAM CARD
CHANNEL
1ll >ID 123456789012 SITE 1127 3423
1X JJ J
2 X JJ J J
3 X JJ J
4 X JJ J J >FLASHDLY
5 X J RELAY DLY 05
6 X J J
7 X J
8 X J J >ANALOG
9 X J TEMP deg. P 55
10 X J LINE VOLTAGE 104
11 X 24V 1 MONITOR 23
12 X
DONE