NEMA SMU-12/16 Level 2 Features and Specifications |
SIZE | 4.5" wide x 10.5" high x 9.1" deep. |
---|---|
POWER REQUIREMENTS | 89 to 135 volts ac. 60 +/- 3 Hertz 1 Amp SLO-BLO fusing |
TEMPERATURE | -34°C to +74°C Operating -40°C to +85°C Storage |
CHANNELS MONITORED | 12 Channels with 4 inputs / channel (Green, Yellow, Walk, Red / Don't Walk). |
MONITORED SIGNALS | Controller Voltage Monitor. +24 Volt dc. (24VI and 24 VII) 48 ac field wire voltages (both polarities of sinusoid are monitored independent of one another). |
DISPLAYED INFORMATION | All active channels on 4 line x 20 character LCD. |
Copyright (c) 1993 Traffic Sensor Corp. Rev. G 2/9/93 >HELP TIME hour:min:sec DATE month/day/year FAULT Disp Faults MESSAGE Disp Mess PGCARD Disp. Prog. C. FLASHDLY Rly Dly SETUP Setup Opt. ERASE Setup Erase DSPSETIUP DiSp. Setup SELFTEST Self Test DONE EXAMPLE: TIME 5 30 30or TIME 12:30:00 To display TIME: TIME EXAMPLE: DATE 05/26/91 To display DATE: DATE The Fault comand is executed with the keypad. EXAMPLE: FAULT Display recorded data 1111111 1234567890123456 ---------------------- |FOO RRWWYR WR R | FIRST SCREEN FOR FAULT ENTRY #FOO |CONFLICT IG 3Y | |DATE 05/26/91 13:20 | --------------------- 111111 1234567890123456 ---------------------- |FOO RRWWYR WR R | NEXT SCREEN FOR FAULT ENTRY #FOO |CONFLICT 1G 3Y | |GGYR RYGG R | ---------------------- 1111111 1234567890123456 ----------------------- |FOO RRWWYR WR R | NEXT SCREEN FOR FAULT ENTRY #FOO |CONFLICT 1G 3Y | |TF= 95 AC=116 24v=24 | ----------------------- EXAMPLE: MESSAGE display recorded data 1111111 1234567890123456 ---------------------- |MOO WY RRWGGRGR | FIRST SCREEN FOR MESSAGE ENTRY |MIN FAIL 4Y | #MOO |DATE 04/27/91 10:45 | ----------------------- 1111111 1234567890123456 ---------------------- |MOO WY RRWGGRGR | NEXT SCREEN FOR MESSAGE ENTRY |MIN FAIL 4Y | #MOO | RRRGYWGR | ----------------------- 1111111 1234567890123456 ---------------------- |MOO WY RRWGGRGR | NEXT SCREEN FOR MESSAGE ENTRY |MIN FAIL 4Y | #MOO |TF=113 AC= 98 24v=26 | ----------------------- EXAMPLE: PGCARD PROGRAM CARD CHANNEL 111 Program Card Jumper location Channels 123456789012 1 XJ <n> Channel 1 Permissive with 2 2 X J <n> Channel 2 Permissive with 4 3 XJ <n> Channel 3 Permissive with 4 4 X <n> Channel 4 Not Permissive 5 X <n> Channel 5 Not Permissive 6 X <n> Channel 6 Not Permissive 7 X <n> Channel 7 Not Permissive 8 X <n> Channel 8 Not Permissive 9 X <n> Channel 9 Not Permissive 10 X <n> Channel 10 Not Permissive 11 X <n> Channel 11 Not Perinissive 12 X <n> Channel 12 Not Permissive